Sigma-Delta ADC is different from Nyquist sample rate ADC. By employing over-sampling principle and noise shaping technique, most noise is removed out of the signal band. Then decimation filter filters out the out-band high frequency shaping noise and achieves higher signal to noise ratio (SNR). The structure reduces sensitivity to analog devices precision and matching.